CBC ZR-DH1621NP Guía de instalación Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
TCOMMAND OPERATING INSTRUCTIONS V1.3 09-03-2009 V18 SOFTWARE.DOC Page 5
3. INSTALLATION
OPERATING VOLTAGE
The T-Command requires 9VDC @ 500mA the LCD back light requires the full 9VDC to start. If the unit is
supplied with less the keyboard will light and then fail. The T-Command can also be supplied with power by
the CAT 5 cable fig 1.
Fig. 1 Note the connections below are at the T-Command & the Tx would be Rx at the MATRIX / CPU end of
the cable.
1 =+9Vdc SUPPLY
2 =+9Vdc SUPPLY
3 = TxA (TO MATRIX / CPU)
4 = RxA (FROM MATRIX / CPU)RxB (FROM MATRIX / CPU) = 5
TxB (TO MATRIX / CPU) = 6
0V SUPPLY = 7
0V SUPPLY = 8
BLUE
WHITE/GREEN
ORANGE
WHITE/BLUE
GREEN
WHITE/BROWN
BROWN WHITE/ORANGE
White/Blue, Blue, White/Orange, Orange, White/Green, Green, White Brown, Brown,
are the recommended CAT5 & 6 Colours
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 19 20

Comentarios a estos manuales

Sin comentarios